Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Bio Mater ; 2(11): 4998-5011, 2019 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-35021498

RESUMO

We present microfabricated poly(dimethylsiloxane) templates assembled atop Transwell membranes ("Chip-on-a-Transwell") for focal delivery of soluble reagents to cells. This modified Transwell operates based on area-selective diffusion of soluble species to the basal side of cells. The device was capable of addressing small groups of cells, with a maximum spatial resolution of 20 µm, while sustaining focal signal for up to 48 hours. Furthermore, we developed a fluorosilane-based cell micropatterning method that complements the Transwell system, creating well-defined arrays of muscle cell cultures and enabling automated microscopy and image analysis protocols. The micropatterning method is based on plasma-etching hydrophilic cell-adhesive tracks against a hydrophobic fluorosilane cell-repellent background. We applied the platform as a model of the neuromuscular junction (NMJ), in which we effectively substituted motor neurons with apertures delivering agrin stimuli to subcellular regions of micropatterned myotubes. With the Transwell system, we demonstrated that focal agrin application to subcellular sections of myotubes induced localized acetylcholine receptor microclustering, mimicking the in vivo NMJ. We also demonstrated spatially selective transfection of a monolayer of cells using Lipofectamine carrying the plasmid DNA for pMax GFP, which is ubiquitously expressed in transfected cells. In summary, we present a user-friendly cell culture tool that provides spatiotemporal control of the fluidic and substrate microenvironments with potential applications to developmental biology and tissue engineering.

2.
Biomicrofluidics ; 8(3): 036504, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-25379080

RESUMO

We have investigated the bonding stability of various silane treatments for the integration of track-etched membranes with poly(dimethylsiloxane) (PDMS) microfluidic devices. We compare various treatments using trialkoxysilanes or dipodal silanes to determine the effect of the organofunctional group, cross-link density, reaction solvent, and catalyst on the bond stability. We find that devices made using existing silane methods delaminated after one day when immersed in cell culture medium at 37 °C. In contrast, the dipodal silane, bis[3-(trimethoxysilyl)propyl]amine, is shown to yield stable and functional integration of membranes with PDMS that is suitable for long-term cell culture. To demonstrate application of the technique, we fabricated an open-surface device in which cells cultured on a track-etched membrane can be stimulated at their basal side via embedded microfluidic channels. C2C12 mouse myoblasts were differentiated into myotubes over the course of two weeks on these devices to demonstrate biocompatibility. Finally, devices were imaged during the basal-side delivery of a fluorescent stain to validate the membrane operation and long-term stability of the bonding technique.

3.
Lab Chip ; 14(2): 302-14, 2014 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-24225908

RESUMO

Gradients of biochemical molecules play a key role in many physiological processes such as axon growth, tissue morphogenesis, and trans-epithelium nutrient transport, as well as in pathophysiological phenomena such as wound healing, immune response, bacterial invasion, and cancer metastasis. In this paper, we report a microfluidic transwell insert for generating quantifiable concentration gradients in a user-friendly and modular format that is compatible with conventional cell cultures and with tissue explant cultures. The device is simply inserted into a standard 6-well plate, where it hangs self-supported at a distance of ~250 µm above the cell culture surface. The gradient is created by small microflows from the device, through an integrated track-etched porous membrane, into the cell culture well. The microfluidic transwell can deliver stable, quantifiable gradients over a large area with extremely low fluid shear stress to dissociated cells or tissue explants cultured independently on the surface of a 6-well plate. We used finite-element modeling to describe the porous membrane flow and molecular transport and to predict gradients generated by the device. Using the device, we applied a gradient of the chemotactic peptide N-formyl-met-leu-phe (fMLP) to a large population of HL-60 cells (a neutrophil cell line) and directly observed the migration with time-lapse microscopy. On quantification of the chemotactic response with an automated tracking algorithm, we found 74% of the cells moving towards the gradient. Additionally, the modular design and low fluid shear stress made it possible to apply gradients of growth factors and second messengers to mouse retinal explant cultures. With a simplified interface and well-defined gradients, the microfluidic transwell device has potential for broad applications to gradient-sensing biology.


Assuntos
Técnicas Analíticas Microfluídicas , Técnicas de Cultura de Tecidos/instrumentação , Dimetilpolisiloxanos/química , Desenho de Equipamento , Análise de Elementos Finitos , Fluorescência , Células HL-60 , Humanos
4.
Stem Cells Dev ; 22(16): 2315-25, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23517131

RESUMO

An improved understanding of the factors that regulate the migration of human embryonic stem cell-derived cardiomyocytes (hESC-CMs) would provide new insights into human heart development and suggest novel strategies to improve their electromechanical integration after intracardiac transplantation. Since nothing has been reported as to the factors controlling hESC-CM migration, we hypothesized that hESC-CMs would migrate in response to the extracellular matrix and soluble signaling molecules previously implicated in heart morphogenesis. To test this, we screened candidate factors by transwell assay for effects on hESC-CM motility, followed by validation via live-cell imaging and/or gap-closure assays. Fibronectin (FN) elicited a haptotactic response from hESC-CMs, with cells seeded on a steep FN gradient showing nearly a fivefold greater migratory activity than cells on uniform FN. Studies with neutralizing antibodies indicated that adhesion and migration on FN are mediated by integrins α-5 and α-V. Next, we screened 10 soluble candidate factors by transwell assay and found that the noncanonical Wnt, Wnt5a, elicited an approximately twofold increase in migration over controls. This effect was confirmed using the gap-closure assay, in which Wnt5a-treated hESC-CMs showed approximately twofold greater closure than untreated cells. Studies with microfluidic-generated Wnt5a gradients showed that this factor was chemoattractive as well as chemokinetic, and Wnt5a-mediated responses were inhibited by the Frizzled-1/2 receptor antagonist, UM206. In summary, hESC-CMs show robust promigratory responses to FN and Wnt5a, findings that have implications on both cardiac development and cell-based therapies.


Assuntos
Células-Tronco Embrionárias/citologia , Matriz Extracelular/efeitos dos fármacos , Fibronectinas/farmacologia , Miócitos Cardíacos/efeitos dos fármacos , Proteínas Proto-Oncogênicas/farmacologia , Proteínas Wnt/farmacologia , Anticorpos Neutralizantes/farmacologia , Adesão Celular , Diferenciação Celular , Movimento Celular/efeitos dos fármacos , Cultura em Câmaras de Difusão , Células-Tronco Embrionárias/metabolismo , Matriz Extracelular/genética , Matriz Extracelular/metabolismo , Fibronectinas/genética , Fibronectinas/metabolismo , Expressão Gênica , Humanos , Imagem Molecular , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Proteínas Proto-Oncogênicas/genética , Proteínas Proto-Oncogênicas/metabolismo , Receptores de Fibronectina/antagonistas & inibidores , Receptores de Fibronectina/genética , Receptores de Fibronectina/metabolismo , Transdução de Sinais , Proteínas Wnt/genética , Proteínas Wnt/metabolismo , Proteína Wnt-5a
5.
Biomicrofluidics ; 5(2): 22210, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21799716

RESUMO

Microfluidics has become increasingly important for the study of biochemical cues because it enables exquisite spatiotemporal control of the microenvironment. Well-characterized, stable, and reproducible generation of biochemical gradients is critical for understanding the complex behaviors involved in many biological phenomena. Although many microfluidic devices have been developed which achieve these criteria, the ongoing challenge for these platforms is to provide a suitably benign and physiologically relevant environment for cell culture in a user-friendly format. To achieve this paradigm, microfluidic designs must consider the full scope of cell culture from substrate preparation, cell seeding, and long-term maintenance to properly observe gradient sensing behavior. In addition, designs must address the challenges associated with altered culture conditions and shear forces in flow-based devices. With this consideration, we have designed and characterized a microfluidic device based on the principle of stacked flows to achieve highly stable gradients of diffusible molecules over large areas with extremely low shear forces. The device utilizes a benign vacuum sealing strategy for reversible application to pre-established cell cultures. We apply this device to an existing culture of breast cancer cells to demonstrate the negligible effect of its shear flow on migratory behavior. Lastly, we extend the stacked-flow design to demonstrate its scalable architecture with a prototype device for generating an array of combinatorial gradients.

6.
Biomicrofluidics ; 4(4): 44105, 2010 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-21124751

RESUMO

Control of the 3D microenvironment for cultured cells is essential for understanding the complex relationships that biomolecular concentration gradients have on cellular growth, regeneration, and differentiation. This paper reports a microfluidic device for delivering gradients of soluble molecules to cells in an open reservoir without exposing the cells to flow. The cells are cultured on a polyester membrane that shields them from the flow that delivers the gradient. A novel "lid" design is implemented which prevents leakage from around the membrane without requiring sealing agents or adhesives. Once layers are molded, device fabrication can be performed within minutes while at room temperature. Surface gradients were characterized with epifluorescence microscopy; image analysis verified that sharp gradients (∼33 µm wide) can be reproducibly generated. We show that heterogeneous laminar flow patterns of Orange and Green Cell Tracker (CT) applied beneath the membrane can be localized to cells cultured on the other side; concentration profile scans show the extent of CT diffusion parallel to the membrane's surface to be 10-20 µm. Our device is ideal for conventional cell culture because the cell culture surface is readily accessible to physical manipulation (e.g., micropipette access), the cell culture medium is in direct contact with the incubator atmosphere (i.e., no special protocols for ensuring proper equilibration of gas concentrations are required), and the cells are not subjected to flow-induced shear forces, which are advantageous attributes not commonly found in closed-channel microfluidic designs.

7.
Lab Chip ; 9(3): 417-26, 2009 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-19156291

RESUMO

Microfluidic perfusion systems, characterized by deterministic flow, low reagent consumption, small dead volumes, large integration in small footprints, high-throughput operation, and low-cost fabrication, are being increasingly used for cell culture studies in applications such as basic cell biology, molecular biological assays, tissue engineering, and systems biology. We report a multipurpose, pressure-driven and computer-controlled microfluidic perfusion device containing sixteen inlets and a large cell culture chamber. The user can choose, with sub-second temporal resolution, (a) to feed the chamber with one of 16 inlets, all 16 inlets, or one of 64 combinations of 2, 4, or 8 inlets using a binary multiplexer; (b) to introduce into the chamber a heterogeneous laminar flow of the inlets, a smoothened gradient, or a fully homogenized mixture; (c) to bypass the chamber in order to purge the inlet lines so as to minimize the dead volume; (d) to generate asymmetrical and curvilinear flow patterns within the chamber by opening side outlets; and (e) to slow down the flow by combinatorially adding segments of high fluid resistance (sixteen different levels of flow rates are possible using only four valves). All functionalities are combined to create complex gradient patterns and sequential perfusions within the central chamber.


Assuntos
Técnicas de Cultura de Células , Técnicas Analíticas Microfluídicas/instrumentação , Perfusão/instrumentação , Algoritmos , Técnicas de Cultura de Células/instrumentação , Dimetilpolisiloxanos/química , Desenho de Equipamento , Fenômenos Físicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...